Use And Maintenance Of Annular High-pressure Blower

When the annular high-pressure blower is running, the current consumed by the motor will increase with the increase of pressure and vacuum. If the current is too large, the contactor will trip. To prevent tripping or save electricity, please increase the cross-sectional area of ​​the air outlet as much as possible, or install a wind pressure and air volume regulating valve on the air intake or exhaust side. The total cross-sectional area of ​​the air outlet should be larger than 1/2 of the equipment outlet cross-sectional area. If it is used for air delivery in water, the water depth pressure should be less than 70% of the maximum static pressure value indicated in the model catalog. When pressurized air is delivered, it is normal for the outlet temperature to be 10 degrees Celsius higher than the normal temperature due to air friction, so an iron pipe of more than 1M should be used. The total cross-sectional area of ​​the suction hole should be larger than 1/2 of the equipment inlet cross-sectional area. Unscrew the filter swivel joint and use an air spray gun or brush to remove the dirt or dust on the filter screen. After cleaning, turn it back and it can be used.